Analysis on the Design Points of Fire Alarm System in Urban Complex
-
摘要: 根据国家标准 GB 50116-2013《火灾自动报警系统设计规范》及其他相关专业规范,本文探讨了城市综合体火灾自动报警系统形式的选择、组成,火灾探测器的选择,消防联动控制系统的设置等问题,并结合具体工程项目给出相关建议及相应的解决方案。Abstract: According to the national standard GB 50116-2013 "Code for Design of Automatic Fire Alarm System" and other related professional specifications, this article discusses the selection and composition of the form and composition of the automatic fire alarm system of urban complexes, the choice of fire detectors, and the setting of the fire linkage control system. Problems, and give relevant suggestions and corresponding solutions in combination with specific engineering projects.
-
Key words:
- urban complex /
- automatic fire alarm system /
- fire control linkage /
- fire detctor
-
[1] 公安部沈阳消防研究所.GB50116-2013,火灾自动报警系统设计规范[S].北京:中国计划出版社,2013. [2] 公安部天津消防研究所.GB50016-2014,建筑设计防火规范(2018版)[S].北京:中国计划出版社,2018. [3] 中国建筑东北设计研究院有限公司.GB51348-2019,民用建筑电气设计标准[S].北京:中国建筑工业出版社,2019. [4] 中国中元国际工程公司.GB50974-2014,消防给水及消火栓系统技术规范[S].北京:中国计划出版社,2014. [5] 公安部四川消防研究所.GB51251-2017,建筑防烟排烟系统技术标准[S].北京:中国计划出版社,2017. [6] 陈技,林洪钟,黄园梅.火灾自动报警系统设计若干问题探讨[J].建筑电气,2019,38(10):39-47.