Abstract:
Based on the current heating status of a heating plant in a park, with known pipe diameters and loads of each section of the heating pipe network, hydraulic calculations, calculations of resistance losses, and heat sources are performed according to the standards and specifications of the heating industry Whether
the heating capacity of the plant can meet the demand of heat load development in recent years, and propose solutions for users who cannot meet the heating demand, and provide a certain reference for the construction and development of the regional heating pipe network.