Cause Analysis and Treatment of Low Ball Collecting Rate of Condenser
-
摘要: 嘉峪关宏晟电热公司 #4 机组凝汽器为哈尔滨汽轮机厂配套生产的 N-19500-1 型凝汽器,该凝汽器配套两套凝汽器管束清洁胶球装置,经常出现收球率低的现象。作者通过设备现状分析,找出三个积球原因,并提出相应的技术方案、工作原理,并通过数据对实施改造后效果进行评价,为系统解决凝汽器收球率的问题提供实际参考,对同类设备具有很大的实用价值。Abstract: The condenser of unit 4 of Jiayuguan Hongsheng electric heating Co., Ltd. is n-19500-1 type condenser produced by Harbin steam turbine works. The condenser is equipped with two sets of condenser tube bundle cleaning rubber ball devices, which often leads to low ball collecting rate.Throughthe analysis of the current situation of the equipment,the author fi nds out three causes of ball accumulation, puts forward the corresponding technical scheme and working principle, and evaluates the eff ect after the implementation of the transformation through the data, which provides a practical reference for the system to solve the problem of ball collection rate of condenser, and has great practical value for similar equipment.
-
Key words:
- condenser /
- rubber ball guide plate /
- ball collecting rate
-
[1] 靖长才.200 MW汽轮机凝汽器胶球收球率低的原因分析及对策[J].电站辅机,1997(3):13-14. [2] 万大报.350 MW机组胶球系统收球率低的治理[J].重庆电力高等专科学校学报,2020(3):4. [3] 门金成.大型燃气-蒸汽联合循环发电技术(三菱F级)[M].北京: 中国电力出版社,2017:11. [4] 刘宏运,杨林冲.凝汽器胶球系统收球率低原因分析[J].工业工程设计,2019(9):21-24.
点击查看大图
计量
- 文章访问数: 19
- HTML全文浏览量: 2
- PDF下载量: 1
- 被引次数: 0