Volume 2 Issue 12
Dec.  2020
Turn off MathJax
Article Contents
JIANG Hongyi. Analysis on the Failure Causes and Preventive Measures of Glass-fibre Reinforced Plastic Spray Pipe[J]. Intelligent Building and Construction Machinery, 2020, 2(12): 50-51.
Citation: JIANG Hongyi. Analysis on the Failure Causes and Preventive Measures of Glass-fibre Reinforced Plastic Spray Pipe[J]. Intelligent Building and Construction Machinery, 2020, 2(12): 50-51.

Analysis on the Failure Causes and Preventive Measures of Glass-fibre Reinforced Plastic Spray Pipe

  • Received Date: 2020-09-06
  • Rev Recd Date: 2020-12-22
  • Available Online: 2022-03-28
  • Publish Date: 2020-12-28
  • A failure of the fiberglass sprinkler would cause the electric generator to shut down. Based on this, this paper analyzes the reasons of the common troubles in the operation of the spray pipe, and puts forward the corresponding preventive measures to provide reference for similar accidents.

     

  • loading
  • [1]
    DL/T 5196-2004,火力发电厂烟气脱硫设计技术规程[S].
    [2]
    HJ/T 179-2005,火电厂烟气脱硫工程技术规范.石灰石/石灰-石膏法[S].
    [3]
    HG/T 21633-1991,玻璃钢管和管件[S].